International Journal of Engineering
Trends and Technology

Research Article | Open Access | Download PDF

Volume 3 | Issue 3 | Year 2012 | Article Id. IJETT-V3I1P234 | DOI : https://doi.org/10.14445/22315381/IJETT-V3I1P234

Implementation Strategy for Optical Fiber Modbus - TCP Based Nuclear Radiation Detection Instrument for Nuclear Emergency


Shripad Shyam Vaijapurkar , S.M. Kate

Citation :

Shripad Shyam Vaijapurkar , S.M. Kate, "Implementation Strategy for Optical Fiber Modbus - TCP Based Nuclear Radiation Detection Instrument for Nuclear Emergency," International Journal of Engineering Trends and Technology (IJETT), vol. 3, no. 3, pp. 462-465, 2012. Crossref, https://doi.org/10.14445/22315381/IJETT-V3I1P234

Abstract

Any detection of Nuclear emergency is prone to the EMP generated by the blast. Hence use of c onventional wireless & wired sensor networks in such scenarios becomes very difficult. Thus an effective sensor network scheme is needed which effectively senses and communicates in such scenarios over an existing protocol. The proposed system offers such a scheme where Optical fiber based communication is used for immunity against EMP, while MODBUS - TCP protocol is used for faster communication over existing network protoco


Keywords

EMP, Nuclear, MODBUS, Fiber Optic LM3S6965, Ethernet, TCP/IP, uIP

References

 [1] Vasily N.Greetsai, Andrey H. Kozlovsky, Vadim M. Kuvshinnikov, Vladimir M. Loborev, Yuri V. Parfenov , Oleg A. Tarasov, a nd Leonid N. Zdoukhov, Response of Long Lines to Nuclear High - Altitude Electromagnetic Pulse (HEMP), IEEE Transactions on Electromagnetic Compatibility, Vol.40, No. 4, November 1998, pp. 348 - 354
[2] Lieutenant Colonel Thomas C. Riddle, United States Army, Nuclear High Altitude Electromagnetic Pulse - Implication s for Homeland security and Homeland defences, pp. 1 - 7 .
[3] Jim Jachetta, Edmund A Williams , National Association of Broadcasters Engineering Handbook, 10 th Edition, Chapter 6.10 – Fiber Optic Trans mission Systems, pp.208 - 211
[4] ACROMAG Incorporated, Wixom, Minnesotta - USA, BUSWORKS 900EN Series, Technical Reference – MODBUS TCP/IP, “ Introduction to MODBUS TCP/IP ”,pp. 1 - 42
[5] Modbus Messaging on TCP/IP Implementation Guide V1.0b, s3.1.3, pp 1 - 35
[6] Adam Dunkels, Swedish Institute of Computer Science, The uIP Embedded TCP/IP Stack, The uIP 1.0 Reference Manual, June 2006. Pp 1 - 23
[7] Pedro Sampaio, Tiago Dias, Centro de Cálculo do ISEL, Lisbon, Portugal, TCP/IP stack optimized for standalone ap plications running on ARM7 processors. pp 1 - 6
[8] Description for TI’s Stellaris series LM3S6965 Ethernet Evaluation Board. (http://www.ti.com/tool/ek - lm3s6965#descriptionArea.

Time: 0.0013 sec Memory: 32 KB
Current: 1.87 MB
Peak: 4 MB