Abstract

Electricity is required to measure power consumption.A Conventional system requires an individual and agent to physically come and take down the readings and report to household or office the amount one must pay. This process is very length and erroneous.So there is increased demand for Automatic Meter Reading (AMR) systems which collect meter readings electronically, and its application is expanding over industrial, commercial and utility environment.The main objective of the project is focused on the application of PLCC (Power Line Carrier Communication). The important advantage of this system is that no additional transmission line is needed for the transmission of data. It gives the useful functionality of switching the power ON or OFF to the user based on the signal sends to it from the controller corresponding to the status Also the Customers can pay their bills at home through the RFID reader. The automated EB billing procedure fulfills a set of needs for the user and the EB workers.


Keywords

AMR, Power Line Carrier Communication,controller,RFID reader

References

[1] Park, B.S, Hyun, D.H, Cho, S.K. “Implementation of AMR system using power line communication”. Conference and Exhibition 2002: Asia Pacific. IEEE/PES, Vol. 1, Oct. 2002, pp. 18-21
[2] Raja, G.T. “Electricity consumption and automatic billing through power line”, Power Engineering Conference, 2007, PP. 1411 – 1415, 2007.
[3]Bharath, P “Wireless automated digital energy meter”, Sustainable energy technologies, International conference, 2008, PP. 564 – 567,2008.
[4]TasfinMohaimeenHaq “Application of Power Line Carrier (PLC) in Automated Meter Reading (AMR)and Evaluating Non-Technical Loss (NTL)” International Journal of Research and Technology ,Vol 2,Issue 8,August 2013.
[5]PoonamBorle,AnkitaSaswadkar,DeepaliHiwarkar,RupaliS.K ad “Automatic Metre Reading For Electricity Using Powerline Communication” International Journal of Advanced Research in Electrical and Instrumentation EngineeringVol2.,Issue 3,March2013.
[6]Mr.VishalKashinathOvhal, Dr.U.L.Bombale”Power Line Communication Based Automatic Electrical Billing Meter and Power Supply Control Using Frequency Shift Keying Modulation”International Journal of Modern Trends in Engineering and Research vol.2, Issue 4,April2015
[7]G.Sujatha, D.Murali, R,Ram Kishore “Automated EB Billing and Supply Control using PowerLineCommunication” vol.45- NO 7,May 2015
[8]V.Manimala,S.K.M.Sangeetha,R.Subhashree,T.V.K.Surekha ”Design and Implementation of Automatic Metre Reading using PLC Modem”South Asian Journal of Engineering and Technology,Vol-3-NO 6,2017